PRODUCTS MBR System
Membrane Reactor MT-MBR
The system consists of an external tank that is installed from 1 to 5 cassettes of membranes maintaining a certain distance between them.
The biologically treated water recirculation arrives to MT-MBR which performance the solid/liquid separation. The MT-MBR has an overflow which is returned the biomass supplied to the MT-MBR back to the biological reactor, allowing the elimination of potential floats. The reactor has also a individual covers for each cassette, which facilitates the possible removal and maintenance.
Components of Equipment
Tank container
Inside the wastewater treatment plant, the tank container MT-MBR constitute the filtration unit, where are submerged the membrane modules. Installation in a separate tank and not integrated into the biological deposit facilitates the maintenance actions as well as to maintain always submerged membranes regardless of the level of the biological reactor.
Cassette MBR
Filtration through MBR Cassettes ensures a high purification performance and retention of viruses and bacteria.
Control Panel
All devices necessary for control and operation of the membrane reactor are located in the control box along with all pumps and blowers, facilitating installation and operation of the plant.
Advantages of MT-MBR
l Compact plant fully assembled transportable to newly built sewage treatment plants and/or modifying and improving existing ones.
l Expandability for being a modular system.
l Increasing the concentration of biomass optimizing the capacity of the plant.
l Simple operation.
l Elimination of the settling process as well as conventional tertiary treatment.
l Process reliability.
l High quality of the effluent through an effective solid / liquid separation, obtaining an effluent free of viruses and bacteria
Parameter | MT-MBR-1 | MT-MBR-2 | MT-MBR-3 | MT-MBR-4 | MT-MBR-4 |
Cassettes Model | MBR6-8E | MBR6-8E | MBR6-8E | MBR6-8E | MBR6-8E |
N° Cassettes | 1 | 2 | 3 | 4 | 5 |
Average production (m3/day) | 48 | 96 | 144 | 192 | 240 |
Installed Power (Kw) | 1.8 | 2.65 | 3.6 | 6.5 | 9.3 |
Air connection (mm) | DN50 | DN65 | DN80 | DN80 | DN100 |
Permeate connection (mm) | DN50 | DN 50 | DN 50 | DN65 | DN65 |
Remark: Production guidance for urban wastewater.