Martin Water
PRODUCTS  UF Membranes

Martin UF Membranes 4" & 8"

PERFORMANCE

MTUF-M-4021

MTUF-M-4040

MTUF-M-8040

Dimension(mm)

Ø90×508

Ø90×1016

Ø200×1016

Membrane   Area(m2)

2.5

5

20

Membrane   Material

PVC, PS Modified, PAN, PVDF,PES

MWCO(Dalton)

50K (6K,30K,100K,200K,300K)

Hollow   Fiber ID/OD (mm)

 1.2/2.0(0.9/1.5, 1.6/2.5, 2.0/3.0)

Initial   Pure Water Flux: (L/㎡.h)

150~300

Maximum   Allow Pressure(MPa)

0.6

Transmembrane   Pressure(MPa)

0.2

Normal   Operation Pressure(MPa)

0.1-0.2

Backwash   Pressure(MPa)

0.1

PH   Value

2-10

Max   Allowable Concentration of Free Chlorine(Long Term)(mg/L)

50

Max   Allowable Concentration of Free Chlorine(Short Term)(mg/L)

<300

Operation   Mode

Cross-flow or Dead-end

Max   Operating Temperature(℃)

<40

Membrane   Characteristics

Hydrophilic/Double skin